<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>مقياس pH Archives - Eagle Systems For Import and Export</title>
	<atom:link href="https://eaglesystemsco.com/product-tag/%d9%85%d9%82%d9%8a%d8%a7%d8%b3-ph/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>إيجل سيستمز &#124; حلول الطاقة المتكاملة والأجهزة العلميةوالمعملية</description>
	<lastBuildDate>Fri, 22 May 2026 15:47:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eaglesystemsco.com/wp-content/uploads/2023/02/cropped-Eagle-Systems-Logo-03-32x32.png</url>
	<title>مقياس pH Archives - Eagle Systems For Import and Export</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ADWA AD111 Standard Professional Portable pH / ORP / Temperature Meter</title>
		<link>https://eaglesystemsco.com/product/adwa-ad111-standard-professional-portable-ph-orp-temperature-meter/</link>
					<comments>https://eaglesystemsco.com/product/adwa-ad111-standard-professional-portable-ph-orp-temperature-meter/#respond</comments>
		
		<dc:creator><![CDATA[Alaa Elaraby]]></dc:creator>
		<pubDate>Fri, 22 May 2026 12:25:49 +0000</pubDate>
				<guid isPermaLink="false">https://eaglesystemsco.com/?post_type=product&#038;p=3219</guid>

					<description><![CDATA[<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>ADWA AD111</strong> is a precision portable meter that simultaneously measures <strong>pH, ORP (mV), and Temperature</strong> in a single compact device — designed for laboratories, water treatment facilities, aquaculture, food production, and field testing.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Built by <strong>ADWA Instruments</strong> (Hungary / Romania) and distributed exclusively in Egypt by <strong>Eagle Systems for Supplies</strong>, the AD111 delivers laboratory-grade accuracy in a rugged, handheld form factor at outstanding value for money.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Key highlights at a glance:</strong></p>
<ul class="[li_&#38;]:mb-0 [li_&#38;]:mt-1 [li_&#38;]:gap-1 [&#38;:not(:last-child)_ul]:pb-1 [&#38;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="font-claude-response-body whitespace-normal break-words pl-2">pH range: −2.00 to 16.00 &#124; Accuracy: ±0.02 pH</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">ORP / mV range: ±1000 mV &#124; Accuracy: ±2 mV</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Temperature: −5.0 to 105.0°C &#124; Accuracy: ±0.5°C</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Automatic 1 or 2-point pH calibration with auto-buffer recognition</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Supplied complete with electrode, temperature probe, buffers and batteries — ready to use out of the box</li>
</ul>
<p>The post <a href="https://eaglesystemsco.com/product/adwa-ad111-standard-professional-portable-ph-orp-temperature-meter/">ADWA AD111 Standard Professional Portable pH / ORP / Temperature Meter</a> appeared first on <a href="https://eaglesystemsco.com">Eagle Systems For Import and Export</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="text-text-100 mt-2 -mb-1 text-base font-bold"><a href="https://eaglesystemsco.com/wp-content/uploads/2026/05/manual_ad110_111.pdf">manual_ad110_111</a></h4>
<h4 class="text-text-100 mt-2 -mb-1 text-base font-bold">Overview</h4>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The ADWA AD111 is the benchmark portable multi-parameter meter for professionals who need reliable, accurate measurements of <strong>pH</strong>, <strong>ORP (Oxidation-Reduction Potential)</strong>, and <strong>Temperature</strong> in a single lightweight instrument.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Manufactured by <strong>ADWA Instruments</strong> — headquartered in Szeged, Hungary with production facilities in Romania — the AD111 combines European engineering precision with outstanding cost-efficiency. It is the preferred choice for water quality laboratories, environmental monitoring, aquaculture farms, swimming pool management, food and beverage QC, and educational institutions across Egypt and the Middle East.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Available from <strong>Eagle Systems for Supplies</strong>, Cairo, with same-day dispatch and fast delivery across Egypt.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">What Makes the AD111 the Right Choice?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Egypt&#8217;s diverse water chemistry — from Nile-fed municipal supplies to industrial process water and agricultural irrigation — demands a meter that handles extreme pH ranges and fluctuating temperatures without compromising accuracy. The AD111 delivers on all three:</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>1. Three Parameters in One Device</strong> Unlike basic pH-only meters, the AD111 measures pH, ORP (mV), and Temperature simultaneously. This eliminates the need for separate instruments, saves bench space, and reduces calibration time.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>2. True ±0.02 pH Accuracy</strong> With ±0.02 pH resolution and automatic temperature compensation (ATC), the AD111 produces results that meet the demands of certified laboratories and quality-control environments — not just basic field checks.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>3. Auto-Buffer Recognition</strong> The 2-point push-button calibration automatically recognises standard buffer solutions at pH 4.01, pH 7.01, and pH 10.01. No manual entry required — the meter identifies the buffer and adjusts calibration instantly.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>4. Complete Out-of-the-Box</strong> The AD111 is supplied with every accessory needed for immediate operation: pH electrode (AD1230B), stainless steel temperature probe (AD7662), calibration buffer sachets (pH 4.01 and pH 7.01), four AA alkaline batteries, and a full user manual. Nothing additional to purchase before your first measurement.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>5. Auto-Off Battery Conservation</strong> The meter powers off automatically after <strong>8 minutes of non-use</strong>, significantly extending battery life in field conditions where accidental power-on is common.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Full Technical Specifications</h3>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Parameter</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Specification</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Model</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">ADWA AD111</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Measurement Parameters</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">pH · ORP (mV) · Temperature</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>pH Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">−2.00 to 16.00 pH</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>pH Resolution</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.01 pH</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>pH Accuracy</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±0.02 pH (at 25°C / 77°F)</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>ORP / mV Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±1000 mV</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>ORP Resolution</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1 mV</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>ORP Accuracy</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±2 mV (at 25°C / 77°F)</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature Range</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">−5.0 to 105.0°C</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature Resolution</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">0.1°C</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature Accuracy</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">±0.5°C (up to 60°C) / ±1°C (outside 60°C)</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>pH Calibration</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Automatic, 1 or 2-point</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Buffer Recognition</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Auto — pH 4.01, 7.01, 10.01</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>ORP Calibration</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Factory-set</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature Calibration</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Factory-set</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature Compensation</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Automatic (ATC) or fixed at 25°C</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Auto-Off</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">After 8 minutes of inactivity</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Display</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Large LCD</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>HOLD Function</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Yes — freezes reading for recording</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Low Battery Indicator</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Yes</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Power Supply</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">4 × 1.5V AA alkaline batteries</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Battery Life</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Approx. 500 hours</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Electrode Connector</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">BNC</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Temperature Probe Connector</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Dedicated jack</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Manufacturer</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">ADWA Instruments — Hungary / Romania</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Origin</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">European Union (EU)</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Warranty</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">1-year manufacturer&#8217;s warranty</td>
</tr>
</tbody>
</table>
</div>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">What&#8217;s in the Box</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The AD111 is supplied complete — ready for immediate use:</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> <strong>ADWA AD111</strong> portable pH / ORP / Temp meter (main unit)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> <strong>AD1230B</strong> pH electrode — Epoxy body, BNC connector, 1 m cable, with tip protector</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> <strong>AD7662</strong> stainless steel temperature probe — 1 m cable</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> pH 4.01 calibration buffer sachet (20 ml)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> pH 7.01 calibration buffer sachet (20 ml)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 4 × 1.5V AA alkaline batteries (pre-installed)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> User manual (English + multilingual)</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Protective carry case/carton box</li>
</ul>
<blockquote class="ml-2 border-l-4 border-border-300/10 pl-4 text-text-300">
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Note:</strong> Additional calibration buffer sachets, replacement pH electrodes (AD1230B), and ORP electrodes are available separately from Eagle Systems.</p>
</blockquote>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Ideal Applications</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The ADWA AD111 is used across a wide range of industries and environments:</p>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Application</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Why AD111</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Water treatment plants</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Monitors pH and ORP for chlorination and disinfection control</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Drinking water laboratories</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Meets accuracy demands for potable water quality testing</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Aquaculture &amp; fish farming</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Tracks pH and temperature for optimal fish health</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Swimming pools &amp; spas</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Controls sanitiser levels via ORP measurement</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Food &amp; beverage production</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">QC testing for process water and product pH</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Soil &amp; agricultural testing</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Field measurement of irrigation water and soil extract pH</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Educational laboratories</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Reliable, easy-to-use meter for universities and schools</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Environmental monitoring</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">River, lake, and wastewater pH and ORP monitoring</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Hospitals &amp; medical labs</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Water purity testing for autoclave and dialysis water</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><strong>Pharmaceutical production</strong></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">In-process pH verification for GMP compliance</td>
</tr>
</tbody>
</table>
</div>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">How to Use the ADWA AD111 — Quick Guide</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Taking a pH measurement:</strong></p>
<ol class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-decimal flex flex-col gap-1 pl-8 mb-3">
<li class="font-claude-response-body whitespace-normal break-words pl-2">Remove the electrode tip protector and rinse with distilled water.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Press <strong>MODE</strong> to select pH mode.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Submerge the electrode in the sample — avoid air bubbles.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Wait for the <strong>HOLD</strong> indicator to appear (stable reading).</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Record the displayed pH value.</li>
</ol>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Calibrating the pH electrode:</strong></p>
<ol class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-decimal flex flex-col gap-1 pl-8 mb-3">
<li class="font-claude-response-body whitespace-normal break-words pl-2">Prepare a fresh pH 7.01 buffer solution.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Submerge the electrode and press <strong>CAL</strong>.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">The meter auto-recognises the buffer and adjusts — confirm with <strong>ENTER</strong>.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">For 2-point calibration, repeat with pH 4.01 or pH 10.01 buffer.</li>
</ol>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Taking an ORP (mV) measurement:</strong></p>
<ol class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-decimal flex flex-col gap-1 pl-8 mb-3">
<li class="font-claude-response-body whitespace-normal break-words pl-2">Press <strong>MODE</strong> to switch to mV/ORP mode.</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Submerge the electrode (ORP-capable electrode required).</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2">Allow the reading to stabilise — use <strong>HOLD</strong> to freeze.</li>
</ol>
<blockquote class="ml-2 border-l-4 border-border-300/10 pl-4 text-text-300">
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Tip:</strong> Always rinse the electrode with distilled or deionised water between samples to prevent cross-contamination.</p>
</blockquote>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">ADWA AD111 vs AD110 — What&#8217;s the Difference?</h3>
<div class="overflow-x-auto w-full px-2 mb-6">
<table class="min-w-full border-collapse text-sm leading-[1.7] whitespace-normal">
<thead class="text-left">
<tr>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">Feature</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">AD110</th>
<th class="text-text-100 border-b-0.5 border-border-300/60 py-2 pr-4 align-top font-bold" scope="col">AD111</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">pH measurement</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /></td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Temperature measurement</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /></td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">ORP / mV measurement</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/274c.png" alt="❌" class="wp-smiley" style="height: 1em; max-height: 1em;" /></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /></td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Supplied temperature probe</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">AD7662</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">AD7662</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Supplied pH electrode</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">AD1230B</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">AD1230B</td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Auto-calibration</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /></td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2705.png" alt="✅" class="wp-smiley" style="height: 1em; max-height: 1em;" /></td>
</tr>
<tr>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">Best for</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">pH + Temp only</td>
<td class="border-b-0.5 border-border-300/30 py-2 pr-4 align-top">pH + ORP + Temp</td>
</tr>
</tbody>
</table>
</div>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Choose AD111</strong> if you need ORP / redox potential measurement — for water disinfection control, aquaculture, or oxidising/reducing process monitoring.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Choose AD110</strong> if pH and temperature measurement is sufficient for your application and budget.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Frequently Asked Questions (FAQ)</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Q: Can the AD111 measure saltwater or seawater?</strong> A: Yes. The wide pH range of −2.00 to 16.00 accommodates saline, alkaline, and acidic solutions, including seawater, industrial effluents, and chemical process waters.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Q: How often should I calibrate the AD111?</strong> A: For general use, calibrate before each measurement session or at a minimum daily. In critical applications (pharmaceutical, food QC), calibrate with each use. Always use fresh, unexpired calibration buffers.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Q: Can I replace the pH electrode?</strong> A: Yes. The AD111 uses a standard BNC connector — the <strong>AD1230B</strong> replacement electrode is available from Eagle Systems. Other ADWA-compatible BNC electrodes also work.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Q: What is ORP / Redox potential and why does it matter?</strong> A: ORP (Oxidation-Reduction Potential) measures the ability of a solution to oxidise or reduce substances. In water treatment, ORP directly indicates the effectiveness of disinfectants such as chlorine and ozone. A positive ORP indicates oxidising conditions; a negative ORP indicates reducing conditions.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Q: Is the AD111 waterproof?</strong> A: The AD111 is splash-resistant but not fully waterproof/submersible. Avoid submerging the main unit. The electrode and temperature probe are designed for immersion in liquid samples.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Q: Does Eagle Systems offer calibration services for the AD111?</strong> A: Yes. Eagle Systems provides calibration verification services and can supply certified NIST-traceable calibration buffers for critical applications. Contact us for details.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Q: What is the warranty on the ADWA AD111?</strong> A: The AD111 carries a <strong>1-year manufacturer warranty</strong> against manufacturing defects. Eagle Systems handles all warranty claims in Egypt — you do not need to contact the manufacturer directly.</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Q: Is the ADWA AD111 suitable for use in Egypt&#8217;s climate?</strong> A: Yes. The operating temperature range of −5°C to 105°C and the automatic temperature compensation make the AD111 fully suitable for Egypt&#8217;s high-temperature environments in both laboratory and outdoor field conditions.</p>
<hr class="border-border-200 border-t-0.5 my-3 mx-1.5" />
<h3 class="text-text-100 mt-2 -mb-1 text-base font-bold">Why Buy from Eagle Systems?</h3>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">Eagle Systems for Supplies is the <strong>authorised distributor of ADWA Instruments</strong> in Egypt, serving laboratories, hospitals, water treatment plants, universities, and industrial facilities across the country.</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f3ed.png" alt="🏭" class="wp-smiley" style="height: 1em; max-height: 1em;" /> <strong>Genuine ADWA products</strong> — not grey imports or counterfeits</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f69a.png" alt="🚚" class="wp-smiley" style="height: 1em; max-height: 1em;" /> <strong>Same-day dispatch</strong> from October City, Giza</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f527.png" alt="🔧" class="wp-smiley" style="height: 1em; max-height: 1em;" /> <strong>After-sales support</strong> — calibration assistance, electrode replacement, technical guidance</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4cb.png" alt="📋" class="wp-smiley" style="height: 1em; max-height: 1em;" /> <strong>Invoice and documentation</strong> — official commercial invoice for institutional procurement</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4ac.png" alt="💬" class="wp-smiley" style="height: 1em; max-height: 1em;" /> <strong>WhatsApp support</strong> — 01015880830</li>
<li class="font-claude-response-body whitespace-normal break-words pl-2"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f310.png" alt="🌐" class="wp-smiley" style="height: 1em; max-height: 1em;" /> <strong>Full ADWA range</strong> — meters, electrodes, buffers, probes and accessories in stock</li>
</ul>
<p>The post <a href="https://eaglesystemsco.com/product/adwa-ad111-standard-professional-portable-ph-orp-temperature-meter/">ADWA AD111 Standard Professional Portable pH / ORP / Temperature Meter</a> appeared first on <a href="https://eaglesystemsco.com">Eagle Systems For Import and Export</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://eaglesystemsco.com/product/adwa-ad111-standard-professional-portable-ph-orp-temperature-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
